Shanmugavel group

DateApr 2016 PlaceDindigul, India

In one of their unit, i-Scan Blue was installed and extensive studies were conducted. They had studied for 5 days continuously the elimination efficiency in actual process during Apr 2016. The results showed about 29 to 30 gms per day of all kinds of white PP contaminations ejected by i-Scan-blue.

By Nos 18-04-16 19-04-16 24-04-16 25-04-16 26-04-16 Avg
Category
All kinds of PP 289 304 346 352 359 330
Polycover 64 55 65 67 83 66.8
Cloths 5 6 8 7 10 7.2
Papers 23 34 54 40 61 42.4
Total 381 399 473 466 513 446.4
By Weight
Category
All kinds of PP 4.43 5.30 4.00 7.18 4.11 5.0
Polycover 14.67 16.75 10.70 10.82 14.14 13.4
Cloths 3.44 1.95 6.28 5.23 3.40 4.1
Papers 6.46 5.00 9.49 6.77 6.60 6.9
Total 29.00 29.00 30.47 30.00 28.26 29.3

The customer seeing the performance of the i-scan blue in the line, decided to add one more i-scan blue at the breaker stage.

They were able to remove about 300 to 400 contaminations per day with 1 i-scan-blue and it increased to about 800 per day with 2 i-scan-blue in the line. Also at the breaker machine much bigger PP contaminations were detected and removed successfully.

Line sequence

Bale plucker
CLP
2Way
Other make CCM
i-scan-blue
ASTA
Stepcleaner
Other make CCM (for colour)
CLC1
i-scan-blue
Other make CCm (for colour)
Dustex